A UK mobile coffee van that trades anywhere.

Generators get you turned away from the best indoor pitches. Wattonomy sizes a clean battery + inverter system for your machines and trading day, with 12V cabling referencing BS 7671 and EN 1648-2 — quiet power for a market hall.

ABYC Certified Master Technician badgeBuilt by anABYC Certified Master Technician
Built to UK (BS 7671) standards · free · no account
A real Wattonomy output — a UK mobile coffee setup
Off-grid wiring diagram · 24 VDesigned with WattonomyPositive (+)Negative (−)Solar (PV)AC loadsSystem groundPower flowSignal (no power)Fuse / breaker100 A · inline PV fuse16 mm²95 mm²300 A · Class T50 mm²50 mm²50 mm²35 mm²1.0 mm²5 A1.0 mm²SOLAR5000 WPV1MPPT150/100MPPT1+DC + BUS12.812.812.812.8+BATTERY BANKGB125.6 V · 400 Ah2 series × 2 parallel → 24 V system400 A · Class TF1MAIN SWITCH≥ 500 AQS1INVERTER24/5000INV1AC DISTRIBUTIONRCD · 25 ADP2BATTERY MONITOR500 ASH1PV ISOLATORQS2DC − BUSCHASSIS GROUNDGNDDC DISTRIBUTION5 A mainDP1DC LOADSAC LOADSon standbySHORE POWERAC1Single-point bond — exactly one; never add a secondInverter bonds N–E off-grid; shore/grid provides it on pass-throughall negatives join the busbar —nothing on the battery sidekeep within 178 mm (7 in) of the battery +DAILY ENERGY BALANCEProduced3,597 WhUsed3,450 WhSurplus+147 Wh/dayOFF-GRID WIRING DIAGRAMSystem24 V · 10.24 kWhBuilt toIEC 60364 / BS 7671ScaleNTSDesign checks• Array needs 3 × SmartSolar 150/100.• This 24 V bank is 2× 12.8 V Victron Lithium NG in series — it needs a Victron BMS (VE.Bus B…
System
24 V
Battery
10.24 kWh
Solar
5000 W
Inverter
MP-II 24/5000
SmartSolar 150/100
200W solar panel25×
Battery → inverter cable
Battery → inverter fuse

Wire & fuse sizes follow EN 1648-2 — each conductor carries its fuse and stays under a 3% voltage drop.

Built to UK (BS 7671) standards
Gauge · fuse · volt-drop sized
Every spec sourced

Plenty of venues simply ban generators.

Indoor markets, halls and a lot of event organisers won’t allow a petrol generator — noise and fumes — which quietly limits where you can earn. A sized battery system trades where they can’t. Wattonomy sizes the bank and inverter to your machines and references BS 7671 for the cabling so it holds up to scrutiny.

What a mobile coffee setup needs to get right.

Quiet, legal-to-pitch power that actually lasts the day.

Trading-day energy

Espresso, grinder, a fridge for the milk, lights and card machine — summed as real Wh for a UK trading day.

Inverter for surge

Sized to start the espresso boiler, with headroom so it never cuts out at the worst moment.

Battery + winter charging

A bank sized to the day, with solar plus alternator/EHU charging — honest about how little UK winter sun delivers.

BS 7671 cabling

12V cable and fusing sized referencing BS 7671 and EN 1648-2; any 230V hook-up side installed and certified by a registered electrician.

What you walk away with — free

Building it for real? Unlock the build binder.

Free gets you a safe, correctly-sized design. The build binder gets you the documents to build it right — and prove it's right.

Printable wiring diagram, yours to keep & tape inside the van
Full parts list, every line sourced
The volt-drop & fusing calculation trail — the "why" behind every spec
Save your build & compare options side by side
Start your design — free

The build binder is a one-time unlock — no subscription, no auto-renew.

Questions

Can I run a mobile coffee van on battery in the UK?

For a single-group setup, yes — a sized battery and inverter run it silently and let you pitch where generators are banned. Many UK traders keep gas for the boiler and battery for everything else; the tool sizes the electrical side either way.

Will solar be enough in a UK winter?

Usually not on its own — UK December sun is very low. The tool sizes a bank plus alternator/EHU charging and shows when you’ll need to plug in, rather than selling you panels that won’t deliver.

Is the wiring to UK standards?

The 12V cabling and fusing are sized referencing BS 7671 and EN 1648-2. The 230V hook-up side should be installed and certified by a registered electrician.

Do I need an account?

No. Design the whole system free, no email required. Accounts are only for saving builds or the printable build binder.

Is this just trying to sell me a kit?

No. The parts list is vendor-neutral and standards-referenced — buy the components anywhere. We make the design, not the markup.

The standards we build to

Plain version: these are the recognized rulebooks your design is sized against, so the numbers hold up to a surveyor, an inspector or an insurer.

Wattonomy applies these standards in its calculations. It is not certified, sponsored or endorsed by ABYC, ISO, NFPA or Victron — it sizes your design to meet what they require, and shows the working.

Design my coffee van power